Please use this identifier to cite or link to this item:
doi:10.22028/D291-48314 | Title: | Subcutaneous Defibrillation and Coronary Sinus Pacing After Ventricular Fibrillation With Right Ventricular Metastasis |
| Author(s): | Tokcan, Mert Abdin, Amr Werner, Christian Almasri, Alhasan Lehr, Alessandro Kulenthiran, Saarraaken Schneider, Günther Kindermann, Ingrid Link, Andreas Kessler, Thorsten |
| Language: | English |
| Title: | JACC. Case Reports |
| Volume: | 31 |
| Issue: | 22 |
| Publisher/Platform: | Elsevier |
| Year of Publication: | 2026 |
| Free key words: | cardiac metastasis coronary sinus pacing renal cell carcinoma subcutaneous implantable cardioverter-defibrillator ventricular fibrillation |
| DDC notations: | 610 Medicine and health |
| Publikation type: | Journal Article |
| Abstract: | Background Cardiac metastases can trigger malignant ventricular arrhythmias and limit transvenous therapy with right ventricular (RV) involvement. Case Summary A 67-year-old patient with metastatic clear-cell renal cell carcinoma and RV metastasis developed ventricular fibrillation during ambulance transport after chest pain and a hypertensive crisis. Coronary angiography revealed severe 3-vessel coronary artery disease, followed by high-risk percutaneous coronary intervention. For secondary prevention, a subcutaneous implantable cardioverter-defibrillator (S-ICD) was implanted because RV lead placement was considered unsafe. Subsequent syncope due to sinus arrest led to discontinuation of beta-blocker therapy and was followed by recurrent ventricular tachycardia treated with 6 appropriate S-ICD shocks. Implantation of a dual-chamber pacemaker with a coronary sinus ventricular lead enabled resumption of beta-blocker therapy, with no further events before discharge. Discussion In RV tumor involvement where transvenous leads may be unsafe, this case highlights a hybrid strategy providing defibrillation and bradycardia support. Take-Home Message S-ICD plus coronary sinus ventricular pacing is a practical option when transvenous RV lead placement is not feasible. |
| DOI of the first publication: | 10.1016/j.jaccas.2026.108064 |
| URL of the first publication: | https://doi.org/10.1016/j.jaccas.2026.108064 |
| Link to this record: | urn:nbn:de:bsz:291--ds-483146 hdl:20.500.11880/42249 http://dx.doi.org/10.22028/D291-48314 |
| ISSN: | 2666-0849 |
| Date of registration: | 21-Jul-2026 |
| Faculty: | M - Medizinische Fakultät |
| Department: | M - Innere Medizin M - Radiologie |
| Professorship: | M - Prof. Dr. Michael Böhm M - Keiner Professur zugeordnet |
| Collections: | SciDok - Der Wissenschaftsserver der Universität des Saarlandes |
Files for this record:
| File | Description | Size | Format | |
|---|---|---|---|---|
| 1-s2.0-S2666084926012234-main.pdf | 10,17 MB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License